Goldenway Environmental Technology Co.,Ltd
plasma deodorant |voc adsorption tower |USP Seal Chemical Pumps|Industrial epoxy flooring | high_efficiency_dust_scrubber | FRP Tank | FRP Fan | FRP Duct | FRP Waste Scrubbers |Chemical Pumps |Factory |Contact
frp

Your Position: HOME >Air pollution control equipments design and manufacturer > FRP Vertical Waste Scrubbers

love brand condom mark
Who is Goldenway
FRP Waste Scrubbers
FRP Duct
FRP Fan
FRP Tank
high_efficiency_dust_scrubber
Industrial epoxy flooring
USP Seal Chemical Pumps
VPO Sealless Vertical Pumps
VPI Sealless Vertical Pumps
MPP Magnetic Priming Pumps
plasma deodorant
voc adsorption tower
equipment
fhn_filtration
Contact
Link
 
 
 
 
 
 
 
 
 
 
 

FRP Vertical Waste Scrubbers

Innovation Design
Brief Introduction:

This purification tower adapts to many equipments which are used for disposaling of unhealthy waste gas.


It's not only widely used, but also high efficiency of purification( more than 95%).
Its equipment resistance is low ,cost of operation is low.

Scope of application: acid gas, basic gas, dust particles, etc.
Applicable industries: chemical industry, metallurgy, electronics, machinery, instruments, electroplating and other industries


Goldenway vertical waste scrubber features:

1、High quality purifying tower body shell:
Purification tower body shell is made of FRP or PP production. FRP is made of glass fiber reinforced vinyl resin, gel coat of the shell adding anti-aging agent, it has a light weight, high strength, anti-corrosion, installed and disassembled freely, etc..Pp polypropylene sheet hot melt welding. It has inner and outer surface smooth, corrosion resistance to strong. These two kinds of materials, are the general production purification tower project materials.

2、、Pumping:
The Taiwan production vertical idling anti-corrosion pump. Its key parts wear, the use of PTFE (plastic king), corrosion part uses polycarbonate. Motor for Taiwan "Datong" or "TECO" brand, the design can be idle, dry to normal running again, strong anti-corrosion performance

4、The Conduit:
The purification tower pipe is divided into the inlet pipe and the exhaust pipe, and the water inlet and outlet pipe fittings adopt PVC pressure pipe, and the exhaust pipe adopts the same material as the purifying tower, namely FRP or PP.

3、Accessories:
Known as the content of impurities contained in exhaust gas purification tower for the main parts as filler (PP) and nozzle (PP), the water level controller (PVC). Packing Raschig rings and Pall ring. He is according to nature, the concentration of exhaust gas and impurity and selected. Select what kind of packing, depends on the exhaust gas in the tower body and reaction time, exhaust gas. Adhesion material multipole blockage. Choose the appropriate packing of purification tower normal use is very important. The nozzle is designed for the purification of the tower and design, it is divided into three layers of spray, professional without blocking screw type multi-layer sprinklers. The water level controller: the water tank in the circulating water, often in the acid and alkali in exchange, the water level controller In order to prevent corrosion all plastic (PVC) products, it is the circulating water to regulate the water level.

5, Electric control box:
Electric control box with rainproof outdoor type, electrical components are imported and used in the motor power is equal to or larger than 11kw delta secondary started. According to the customer demand, control box can be installed with pH indicator, ammeter, voltmeter, overheating protection and automatic alarm device.

6.Enhanced anti-corrosion fan:
The shell and impeller are made of glass fiber reinforced vinyl resin. The fan has high strength, good corrosion resistance, and the bracket is made of steel plate bending and welding, and the surface is treated with EPOXY corrosion protection.
Advantage for the FRP Waste Scrubber

1.Through the ISO9001:2000 certification
2.National high and new certified products
3.Appearance design patent product
4.Core technology patents
5.Exhaust C installation qualification
6.Three mechanical and electrical installation qualification

Main technical index
1.Nitrogen oxide,Purification efficiency of more than 95%
2.Sulfuric acid mist,Purification efficiency more than 95%
3.Hydrochloric acid mist,Purification efficiency more than 95%
4.Chromic acid, cyanide,Purification efficiency more than 90%
5.Hydrofluoric acid,Purification efficiency more than 95%
Standard Specification for GOLDENWAY Vertical FRP Washing Tower
Serial number
Handle air volume range(n3/h))
Reference air vplume
Diameter
Variable diameter C(mm)
The tower B(mm)
Total height D (mm)
Air outlet
Feeding height
Tank depth
Air inlet
Window
1
1800-3400
3000
¢1000
400
3000
3400
420
800
H=65
420
400*300
2
2600-4000
4500
¢1200
450
3000
3450
450
800
450
3
4700-7000
6000
¢1600
500
3700
4200
600
800
H=700
600
500*400
4
6000-9000
8000
¢1800
700
3900
4600
700
800
700
5
7500-11000
11000
¢2000
700
4100
4800
750
1000
750
6
13000-16000
16000
¢2200
700
4400
5100
900
1000
900
7
15500-20000
20000
¢2500
900
4500
5400
1050
1000
1050
600*400
8
20000-30000
30000
¢2700
1050
4500
5550
1050
1000
1050
9
22000-32000
25000
¢2800
1000
4600
5600
1100
1200
1100
10
25000-37000
30000
¢3000
1100
4500
5600
1100
1200
H=750
1100
11
28000-42000
35000
¢3200
1100
4500
5600
1200
1200
1200
12
32000-50000
45000
¢3400
1100
4800
5900
1200
1200
1200
650*450
13
39000-59000
50000
¢3800
1200
4900
6100
1400
1200
1400
Explain:
1.The above products for my company product specifications, the mould manufacturing assembling laminated molding;
2.The product surface is smooth and beautiful, the lining material can choose the suitable model according to the gas quality.;
3.My secretary. Other specifications can be customized according to customer demand.

Performance parameter selection table

Model(SCRUBBER-XGH)
Airflow(M3/H)
Auxiliary fan
Mathing water pump
Outline dimension
Modle(Fan-Sys)
Power Hp/kw
Static pressure
Model(KD)
Lift(m)
Power Hp/kw
Diameter mm
Height mm
Air inlet LxW
Air outlet mm
1200
6000-9000
XGH-030
7.5/5.5
140/1400
50vK-35
12
3/2.2
1200
4200
450*300
450
1500
10000-13000
XGH-040
10/7.5
140/1400
50vk-55
14
5/4
1500
4200
550*360
550
1800
14000-16000
XGH-045
15/11
120/1200
50vk-55
14
5/4
1800
4200
650*420
650
2000
17000-20000
XGH-050
20/15
150/1500
65vk-55
14
5/4
2000
4600
750*500
750
2200
21000-25000
XGH-055
25/18.5
165/1650
65vk-55
14
5/4
2200
4600
850*550
850
2500
26000-32000
XGH-060
30/22
160/1600
65vk-7.55
16
7.5/5.5
2500
4600
880*600
900
2800
33000-37000
XGH-070
40/30
160/1600
65vk-7.55
16
7.5/5.5
2800
4600
900*650
950
3000
38000-42000
XGH-070
50/37.5
150/1600
65vk-7.55
16
7.5/5.5
3000
4800
950*680
1000
3200
43000-50000
XGH-080
50/37.5
175/1750
65vk-105
18
10/7.5
3200
4800
1050*800
1150
3500
51000-62000
XGH-080
60/45
150/1500
65vk-105
18
10/7.5
3500
4800
1080*840
1200
Instructions for use

1、In th e use of the device before the first inspection of the various components such as pumps, fans are operating normally, the valve open absorption liquid circulation pipeline to maintain flow.
2、Allocation and liquid drugs must be filtered into the solution tank, avoid water inlet filter cover because the magazine is blocked by a predetermined amount. Neutralizing drugs manual and automatic join, the drug should be according to the concentration of waste, waste gas quantity to adjust the concentration and the addition of velocity.
3、To supplement the water valve of the switch to strengthen management, so that the liquid level in the tank before the start of the pump to reach the height of the overflow port to ensure the normal start of the circulating water pump, but also to prevent the loss of control of the loss caused by loss of water.
4、The circulating water pipe through a bypass valve control loop tube pressure gauge is generally maintained at 1-1.5kg/cm2.
5、Regularly check the concentration of absorption solution, two sodium oxide (NAOH) concentration in 3-6%, sodium sulfide (Na2S) concentration of 2-3%.
6、Each one to February, clean the tank once again, to re configure the new absorbent.
7、Purification tower tank circulating water on a regular basis to replace, generally in 15-30 days, the frequency of replacement of circulating water (cycle), should be adjusted according to the nature of the waste.
8、Weekly check a fan bearing seat level, below the oil standard 50% should be added. Weekly check a fan fastener, fan is in the 24 hours of high speed continuous operation of the machine, the fastener even locking, to improve the service life of the ventilation system is very important. The fan belt in the three months after the operation should be adjusted once, after every six months for an adjustment.
9、Fan FRP and pump switch program:Boot time:First open the fan, after the opening of the pump Off time:First off the pump, after the clearance of the wind turbine

Goldenway offers a full line of products made of fiberglass-reinforced polymer (FRP). Strong, lightweight and corrosion-resistant, these products provide a versatile alternative to traditional materials. Click any FRP category for more details